kVA vs kWh: what the numbers on an inverter mean
Two numbers decide whether a backup system works for you. Here is what each one means, in plain language, and how to size both.
Powerlabs Energy ·
Every inverter and battery system has two headline numbers. Most buying mistakes come from mixing them up.
kVA: how much can run at once
The kVA rating is the inverter’s power: the most it can deliver at any moment. Add up the watts of everything you want to run at the same time. That total, plus headroom, has to fit under the kVA rating.
Motors are the catch. A fridge, freezer, air conditioner or borehole pump draws two to three times its running power for a second or two when it starts. That start-up surge also has to fit.
kWh: how long it can run
The kWh rating is the battery’s storage: how much energy it holds. A 100 W load running for 10 hours uses 1,000 Wh, or 1 kWh.
To work out what you need, multiply each appliance’s watts by the hours you use it, and add them up. Then allow for the fact that a battery shouldn’t be fully drained, and that the inverter loses a little energy converting it.
Getting both right
- Too little kVA: the system trips when you switch on the iron or the AC starts.
- Too little kWh: everything works, but the battery runs flat before morning.
Our sizing tool does this maths for you and matches the result to an iTEN model. A Powerlabs engineer then confirms the design on site.